Assessment of Thyroid Gland in Children with Point-of-Care Ultrasound (POCUS): Radiological Performance and Feasibility of Handheld Ultrasound in Clinical Practice [J Clin Res Pediatr Endocrinol]
J Clin Res Pediatr Endocrinol. Ahead of Print: JCRPE-48343 | DOI: 10.4274/jcrpe.galenos.2024.2023-8-17

Assessment of Thyroid Gland in Children with Point-of-Care Ultrasound (POCUS): Radiological Performance and Feasibility of Handheld Ultrasound in Clinical Practice

Ahmet Anık1, Mustafa Gök4, Göksel Tuzcu2
1Aydın Adnan Menderes University, Faculty of Medicine, Department of Pediatrics, Division of Pediatric Endocrinology, Aydın, Türkiye
2Aydın Adnan Menderes University, Faculty of Medicine, Department of Radiology, Aydın, Türkiye
3University of Sydney, Faculty of Medicine, Department of Health Sciences
4Aydın Adnan Menderes University, Faculty of Medicine, Department of Radiology, Aydın, Türkiye and University of Sydney, Faculty of Medicine, Department of Health Sciences

INTRODUCTION: Point-of-Care Ultrasound (POCUS) refers to the use of portable ultrasound machines to perform quick and focused ultrasound examinations at a patient's bedside or point-of-care. POCUS can be performed by all health workers with specific training to use POCUS. This study aimed to investigate the radiological performance and feasibility of POCUS using a handheld ultrasound (HHUSD) system in children from the perspective of the thyroid gland perspective.
METHODS: A pediatric endocrinologist performed thyroid imaging in children referred to our hospital with suspected thyroid disease using an HHUSD system. The same children underwent US imaging using the same device by the first radiologist, and a second radiologist performed thyroid US using an advanced high-range Ultrasound Device (AHUSD) (defined as the gold-standard method) within two hours. The data obtained by the three researchers were compared with each other.
RESULTS: This study included 105 patients (68.6% girls [n=72)]; mean age 12.8±3.6 years]. When the thyroid volume was evaluated, a strong correlation was found between the measurements of the three researchers (AA vs. MG: r=0.963, AA vs. GT: r=0.969, MG vs. GT: r=0.963, p<0.001). According to the Bland-Altman analysis, for total thyroid volume, AA measured 0.43 cc (%95 CI: -0.89-0.03) smaller than MG, and 0.11 cc (%95 CI: -0.30-0.52) larger than GT, whereas MG measured 0.52 cc (%95 CI: 0.09-0.94) larger than GT. When evaluated for the presence of goiter and nodules, a near-perfect agreement was found between the results of the three researchers (AA vs GT; κ=0.863, MG vs GT; κ=0.887, p<0.001, and AA vs GT; κ=1.000, MG vs GT; κ=0.972, p<0.001, respectively). When evaluated in terms of the longest axis of nodules, a high correlation was found between the measurements of the three researchers (AA vs MG; r=0.993, AA vs GT; r=0.996, MG vs GT; r=0.996, p<0.001). When evaluated in terms of the final diagnosis, the evaluations of the three researchers showed excellent agreement with each other (AA vs GT; κ=0.893, MG vs GT; κ=0.863, p<0.001, Accuracy rate AA vs GT: 93.3%; MG vs GT: 91.4%).
DISCUSSION AND CONCLUSION: A pediatric endocrinologist, equipped with sufficient training in thyroid US evaluation, incorporates the HHUSD as a routine tool for clinical examinations in outpatient settings, they can effectively assess normal thyroid tissue in pediatric patients. Moreover, the HHUSD system proves to be useful in detecting thyroid pathologies. However, it is crucial to note that for a more comprehensive evaluation of thyroid nodules, including detailed assessment and Thyroid Imaging Reporting and Data System “TIRADS” classification, patients should be referred to radiology departments equipped with AHUSD systems. These specialized devices, along with the expertise of radiologists, are essential for in-depth evaluations and accurate classification of thyroid nodules.

Keywords: Handheld ultrasound, imaging, pediatric, point-of-care ultrasound, tyroid pathologies